Detection of coronary artery stenoses using breath-hold magnetic resonance coronary angiography. Comparison with conventional x-ray angiography
C. Gaudio, G. Tanzilli, A. Vittore, M. Arca*, F. Barillà, S. Di Michele, G. Minardi**, F. Fedele, M. Lombardi***, L. Donato*** Department of Cardiology, “La Sapienza” University of Rome – Rome (Italy)
* Department of Medical Therapy, “La Sapienza” University of Rome – Rome (Italy)
** Cardioscience Department, “S. Camillo” Hospital – Rome (Italy)
*** Clinical Physiology Institute, C.N.R. – Pisa (Italy)
Purpose: To detect coronary artery stenoses, we compare breath-hold magnetic resonance coronary angiography (MRCA) to conventional coronary angiography (CA).
Materials and Methods: Sixty-five patients with suspected coronary artery disease underwent MRCA and CA within one week. MRCA examination was performed by using the two-dimensional (2D) breath-hold technique with a fast spoil gradient-echo sequence/spiral. Each imaging sequence was obtained within one breath-hold in expiration (14 seconds of apnoea). The assessment of coronary artery stenoses on magnetic resonance (MR) angiograms was independently performed by two blinded readers and compared to conventional CA images.
Results: Three hundred and ninety segments were evaluated by the two imaging techniques. MRCA correctly detected 76 of 88 (86%) stenoses, and recognized 242 of 302 (80%) not affected segments. The Pearson correlation coefficient between MRCA and CA in assessing coronary narrowings was very high: r = 0.85. Despite this the mean difference was 4.5 with a standard error of estimate of 0.21, indicating that MRCA slightly overestimates the degree of stenoses.
Conclusions: Our study showed that 2D breath-hold MRCA is an accurate technique in displaying and quantifying the most significant stenoses in the proximal and middle segments of the coronary arteries.
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License
To cite this article
C. Gaudio, G. Tanzilli, A. Vittore, M. Arca*, F. Barillà, S. Di Michele, G. Minardi**, F. Fedele, M. Lombardi***, L. Donato***
Detection of coronary artery stenoses using breath-hold magnetic resonance coronary angiography. Comparison with conventional x-ray angiography
Eur Rev Med Pharmacol Sci
Year: 2004
Vol. 8 - N. 3
Pages: 121-128